Results of testbeam with Marebo chip

The 'Marebo' chip has been measured in the H8 test beam at Cern in may 1998. They are 50 x 432 um^2 pixels bonded on a 300 um thick Si detector.

Compared with FEA-FEB analyses, cuts 1, 5, 6 are standard.

Cut 2 is needed to reject those bad pixels with process failure (dead pixels).

Cut 3. These columns show efficiency problem. Col 4 had clearly bit 1 missing.

Cut 4. Minor cut to improve efficiency at edge of pixel

Cut 7: This gains between 1 and 2.5 % of efficiency depending on the chip. This may be related to the beam intensity i.e. the chip activity. No late bit was used in the Marebo chip.


MTh